8
Repeat steps 1-5 (and possibly 8 and 7) until the fiber appears clean. If you repeat this
procedure three times and the fiber still appears dirty, throw out the fiber as it is likely
scratched.
2 Setup for Testing an Optical Link with the HST-3000
This section describes setup and testing when the location in the field is an optical drop.
Step
1
The first step is turning the unit on and then
hitting the home key. Then select the Eth
Optical tab and select option 1 1G Terminate.
2
The unit will now boot up. Make sure to insert the proper SFP into the R/T 1 slot (top
left of the unit). The proper SFP will be either a 1310nm or 850nm optical SFP
depending on the handoff.
3
The next step is to select Layer 2 Traffic as your Test selection.
4
Now press the configure button on the tester.
Then select RFC 2544 Mode = Disable and
Auto Negotiation and depending on the network
select On or Off (most likely this will be set to
on). Next press the home key.
5
Now select the Action tab and then select Laser
On.
6
You should see the screen turn green. If not,
select the display key and then select the
summary result pane. Then select the restart
key on the right side.
Directions
2