Thermo-chiller
Hide thumbs Also See for HRR010-A-10 Series:
Table of Contents

Advertisement

HRX-OM-X084
Chapter 8 Control, Inspection, Exchange and Cleaning
4.
The connection fitting of the DI filter and the tube is connected by a fastener. O ring is used
for the connection fitting. After removing the fastener, remove the connection fitting. Be
careful not to apply force to the tube at this time. Also, please be careful not to damage the O
ring.
Both the IN side and the OUT side have the same shape. Remove the connection fitting on
both sides and remove the DI filter.
Connection
fitting
fastener
5.
Install the DI filter in the reverse procedure that you removed.
There is no flow direction in the DI filter.
Connect the DI filter IN side tube and the DI filter OUT side tube.
6.
Fix DI filter with DI filter fixing band.
7.
Install the filter panel. (Recommended tightening torque:1.5N・m)
8.4 Replacement of consumables