1.
Apply thread sealant to all non-swivel pipe threads.
Apply anti-seize to threads.
2
Torque to 60 +/- 5 ft-lb (81.3 +/- 6.7 N•m) with pot
3
pressurized.
3A3489T
The hand-way gasket must be installed centered and flat on
7
the hand-way cover.
Apply anaerobic sealant to threads.