Setup; Fill Pot With Abrasive Media - Graco EcoQuip 2 EQm Instruction Manual

Hide thumbs Also See for EcoQuip 2 EQm:
Table of Contents

Advertisement

Setup

Setup

Fill Pot with Abrasive Media

1. Verify that the pot seal plunger (E) is in the DOWN
position. If the plunger is in the UP position, perform
the Pressure Relief Procedure on page 17.
2. Verify that all Installation procedures, beginning on
page 10, have been completed.
3. Close the rinse ball valve (U) and abrasive ball
valve (J).
4. Turn the selector valve (T) to OFF.
14
5. Open the pot dump valve (F) and quick drain valve
(ZH).
6. Prepare the pot to accept media:
-
To fill an empty pot: Fill approximately half the
pot (C) with water, until the water drains from
the quick drain valve (ZH). Shut the quick drain
valve.
-
To refill the pot during operation: Open the
quick drain valve (ZH) to drain the water until
the pot is approximately half full. Shut the quick
drain valve.
F
ZH
7. For systems with water tank supply only: if the
water in the tank is less than halfway full, fill the tank
with fresh water.
C
ti39817a