Displacement pump for ultra max 695, series a ultimate mx 695, series a ultra 395/495/595 ultimate nova 395 ultimate super nova 495/595 st max 395/495/595 performance max 395/495/595 ultra max 695, series b ultra 695, series a ultimate mx 695, series b ul (14 pages)
Instructions Displacement Pump - For portable spray application of architectural paints and coatings - Model 288466, 288467, 288468, 288819 3300 psi (22.8 MPa, 25 bar) Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.
Page 2
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.
Service Pressure Relief Procedure The system pressure must be manually relieved to pre- vent the system from starting or spraying accidentally. To reduce the risk of an injury from accidental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you, •...
Page 4
Repair Repair See your sprayer instruction manual for complete instructions for removing and installing the pump in your sprayer. Disassembly 1. (Fig. 1) Remove packing nut (3). 2. (Fig. 2) Unscrew intake valve from cylinder. ti8846a 3. (Fig. 3) Disassemble intake valve. Clean and inspect o-ring (17).
Page 5
Do not clean or wipe piston valve (6) threads. Clean- ing the piston valve threads could destroy the special sealing patch and cause the piston valve to come loose during operation. 6. (Fig. 6) Unscrew piston valve (6) from piston rod (5). Clean and inspect parts.
Page 6
Note: For steps 1-4 refer to Fig. 9. 1. Stack male gland (7) on piston rod (5). 2. Alternately stack blue UHMWPE (8) and brown UHMWPH (9) (288466, 288467, 2884680) or leather (288819) packings on piston rod. Note orientation. 3. Install female gland (10).
Page 7
(4). Slide sleeve (4) into bottom of cylinder (2). Replace o-ring (15) if desired. Place inside cylinder (2) and push to shoulder with sleeve (4). 288466 288467/ 288468 . 14 288819 Note: O-ring (15) is not required for safe pump opera- tion.
Graco Standard Warranty Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.