Technical date
Specifications
Product type:
Standards:
Installation:
Rated Voltage:
Installation systems:
Charging Type:
Protection Class:
Mechanical Impact Resistans:
Temperature Range:
Storage temperature:
Weight:
EMC Classification:
Installation environment:
Location type:
Charging method
Rated current withstand
Rated short-time withstand current
Rated conditional short-circuit current of an assembly
Short-circuit protective device type
Rated impulse withstand voltage
Rated insulation voltage
Rated current of each circuit
Rated diversity factor
Pollution degree:
EMC environmental condition
Software update
See user manual on www.garoemobility.se/support
Service / Maintenance
See user manual on www.garoemobility.com/support
Troubleshooting / Support
See user manual on www.garoemobility.com/support
All Castra CLS1 modeller
IEC 61851-1 and IEC TS 61439-7
Ground/Pole
230V/400V 50Hz
TT-, TN- och IT-systems
Mode 3
IP44
IK10
-25
C – +40
C
0
0
-35
C – +55
C
0
0
22,5 - 24,5 kg depending on model
2014/30/EU
Indoor / Outdoor
Non-restricted Access
AC Charging
10kA
10kA
10kA
Type C
4kV
230/400V
10-16A depending on model
RDF=1
3
A and B
EN
5