Quectel BC26 Manual page 22

Nb-iot module
Table of Contents

Advertisement

The <AcT> access technology selected parameters should only be used in terminals capable to register
to more than one access technology. Selection of <AcT> does not limit the capability to cell reselections,
even though an attempt is made to select an access technology, the phone may still re-select a cell in
another access technology.
AT+COPS Operator Selection
Write Command
AT+COPS=[<mode>[,<format>[,<oper
>[,<AcT>]]]]
Read Command
AT+COPS?
Test Command
AT+COPS=?
Parameter
<mode>
Integer type
0
Automatic mode; <oper> field is ignored
1
Manual operator selection; <oper> field shall be present
2
Manual deregister from network
3
Set only <format> (for read command AT+COPS?),
command response
4
Manual/automatic selected; if manual selection fails, automatic mode (<mode>=0)
is entered
<format>
Integer type
0
Long format alphanumeric <oper>; can be up to 16 characters long
1
Short format alphanumeric <oper>
BC26_AT_Commands_Manual
Response
OK
If there is any error, response:
+CME ERROR:<err>
Response
+COPS:<mode>[,<format>,<oper>][,<AcT>]
OK
If there is any error, response:
+CME ERROR:<err>
Response
+COPS:[list of supported (<stat>,long alphanumeric <oper>,
short
alphanumeric
<oper>[,<AcT>])s][,,(list of supported <mode>s),(list of
supported <format>s)]
OK
If there is any error, response:
+CME ERROR:<err>
NB-IoT Module Series
BC26 AT Commands Manual
<oper>,
not shown in Read
numeric
22 / 73

Hide quick links:

Advertisement

Table of Contents
loading