Quectel BC26 Manual page 20

Nb-iot module
Table of Contents

Advertisement

quality.
The set command controls the presentation of an unsolicited result code. If <n>=1, "+CSCON:<mode>" is
sent from the MT when the connection mode of the MT is changed. When the MT is in UTRAN or
E-UTRAN, the mode of the MT refers to idle when no PS signaling connection and to connected mode
when a PS signalling connection between UE and network is setup.
When the UE is in GERAN, the mode refers to idle when the MT is in either the idle state or the standby
state and to connected mode when the MT is in ready state.
The read command returns the status of result code presentation and an integer <mode> which shows
whether the MT is currently in idle mode or connected mode.
The test command returns supported values as a compound value.
AT+CSCON Signalling Connection Status
Write command
AT+CSCON=[<n>]
Read Command
AT+CSCON?
Test Command
AT+CSCON=?
Parameter
<n>
Integer type
0
Disable unsolicited result code
Enable unsolicited result code: "+CSCON:<mode>"
1
<mode>
Integer type; indicates the signalling connection status
0
Idle
1
Connected
Example
BC26_AT_Commands_Manual
Response
OK
If there is any error, response:
+CME ERROR:<err>
Response
+CSCON:<n>,<mode>[,<state>]
OK
If there is any error, response:
+CME ERROR:<err>
Response
+CSCON:(list of supported <n>s)
OK
NB-IoT Module Series
BC26 AT Commands Manual
20 / 73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents