Specifications - Omron E3X-MDA11 Installation Instructions Manual

2-channel fiber sensors
Hide thumbs Also See for E3X-MDA11:
Table of Contents

Advertisement

Accessories (Order Separately)
Mounting Bracket
Appearance
End Plate
Appearance

Specifications

Ratings/Characteristics
Amplifier Units
Model
NPN output
Item
PNP output
Light source (wavelength)
Supply voltage
Power consumption
Control output
Circuit protection
Super-
high-
speed
Response
mode
time
Standard mode
High-resolution mode
Sensitivity setting
Power tuning
Timer function
Automatic power con-
trol (APC)
Functions
Zero-reset
Initial reset
Mutual interference
prevention
I/O settings
Display
Digital display
Display orientation
Ambient illumination
(receiver side)
E3X-MDA
Model
E39-L143
Model
PFP-M
Type
E3X-MDA11
E3X-MDA41
(current consumption: 45 mA max. at power supply voltage of 24 VDC)
Reverse polarity for power supply connection, output short-circuit
NPN
PNP
Light emission power and reception gain, digital control method
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Display can be reset to zero when required (negative values can be displayed).
Output setting (Select from channel 2 output, AND, OR, leading edge sync, falling edge sync, or
Operation indicator for channel 1 (orange), Operation indicator for channel 2 (orange)
Select from the following: Incident level for channel 1 + incident level for channel 2, Incident level
+ threshold, incident level percentage + threshold, incident light peak level + no incident light bot-
tom level, minimum incident light peak level + maximum no incident light bottom level, long bar
Quantity
1
Quantity
1
2-channel models
Red LED (650 nm)
12 to 24 VDC ±10%, ripple (p-p) 10% max.
1,080 mW max.
Load power supply voltage: 26.4 VDC; open collector;
load current: 50 mA max.; residual voltage: 1 V max.
130 µs
*1
for operation and reset respectively
1 ms for operation and reset respectively
4 ms for operation and reset respectively
Teaching or manual method
Select from OFF-delay, ON-delay, or one-shot timer.
High-speed control method for emission current
Settings can be returned to defaults as required.
Possible for up to 9 Units (18 channels)
differential output)
display, incident level + peak hold, incident level + channel
Switching between normal/reversed display is possible.
Incandescent lamp:10,000 lux max.
Sunlight:20,000 lux max.