Ratings And Specifications - Omron E3X-NA Manual

Fiber amplifier
Hide thumbs Also See for E3X-NA:
Table of Contents

Advertisement

Ratings and Specifications

Amplifier Units
Type
Standard models
NPN
E3X-NA11
output
Model
PNP
Item
E3X-NA41
output
Light source
Red LED (680 nm)
(wavelength)
Power supply
12 to 24 VDC ±10%, ripple (p-p): 10% max.
voltage
Current
35 mA max.
consumption
Control output
Load current: 50 mA max.; residual voltage: 1 V max.; NPN/PNP (depends on model) open collector; Light-ON/Dark-ON mode selector
Self-diagnosis
None
output
Operate or reset: 200 μs max.
Response time
Sensitivity
8-turn sensitivity adjuster (with indicator)
adjustment
Reverse polarity, output short-
Protection circuits
circuit, mutual interference pre-
vention (optically synchronized)
Timer function
OFF-delay timer: 40 ms (fixed)
Ambient illumination
Incandescent lamp: 10,000 lux max.
(Receiver side)
Sunlight:
Operating:Groups of 1 to 3 Amplifiers: −25°C to 55°C
Groups of 4 to11 Amplifiers: −25°C to 50°C
Ambient
Groups of 12 to16 Amplifiers: −25°C to 45°C
temperature range
Storage: −30°C to 70°C (with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
range
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance
Destruction: 500 m/s
Degree of protection
IEC 60529 IP50 (with Protective Cover attached)
Connection method
Pre-wired (standard cable length: 2 m)
Weight
Approx. 100 g
(packed state)
Case
Polybutylene terephthalate (PBT)
Material
Cover
Polycarbonate
Accessories
Instruction manual
* When there are 8 or more Units mounted side-by-side, the response time will be 350 μs max.
Amplifier Unit Connectors
Item
Model
Rated current
2.5 A
Rated voltage
50 V
20 mΩ max. (20 mVDC max., 100 mA max.)
Contact resistance
(The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.)
Number of inser-
Destruction: 50 times (for connection to the Amplifier Unit and the adjacent Connector)
tions
Housing
Polybutylene terephthalate (PBT)
Material
Contact
Phosphor bronze/gold-plated nickel
Weight
Approx. 55 g
(packed state)
http://www.ia.omron.com/
Amplifier Units with Cables
High-speed
detection models
E3X-NA21
E3X-NA11F
E3X-NA51
E3X-NA41F
35 mA max.
(for 24-VDC power
supply)
Yes
None
Operate: 20 μs max.
*
Reset: 30 μs max.
Reverse polarity,
output shortcircuit
20,000 lux max.
2
, for 3 times each in X, Y and Z directions
E3X-CN11
Mark-detecting
Water-resistant
models
models
E3X-NAG11
E3X-NA11V
E3X-NAG41
E3X-NA41V
Green LED
Red LED (680 nm)
(520 nm)
35 mA max.
Operate or reset: 200 μs max.
*
Reverse polarity, output short-circuit, mutual interference prevention (optically syn-
chronized)
IEC 60529 IP66
(with Protective
Cover attached)
Approx. 110 g
Polyethersulfone
(PES)
Approx. 25 g
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
E3X-NA
Amplifier Units with Connectors
Water-resistant
Standard models
models
(M8 connectors)
E3X-NA6
E3X-NA14V
E3X-NA8
E3X-NA44V
500 VAC at 50/60
Hz for 1 minute
IEC 60529 IP50
IEC 60529 IP66
(with Protective
(with Protective
Cover attached)
Cover attached)
Standard
Standard M8
connector
connector
Approx. 55 g
Approx. 65 g
Polyethersulfone
Polycarbonate
(PES)
E3X-CN12
3

Hide quick links: