IMPORTANT SAFETY
Please read and follow these important instructions to help ensure your safety and the quality performance of your Kasco equip-
ment�
Use caution when dealing with any electrical and/or moving equipment�
Under NO CIRCUMSTANCE should anyone enter the water with the electrical equipment plugged in and/or in operation�
Kasco Aerating Fountains are intended for use with a Listed control panel having a GFCI protected receptacle, or field wiring
terminals and disconnect switch, or a timer with a disconnect for use with a GFCI receptacle� Control panels MUST be installed by
a qualified electrician. Ground Fault Circuit Interrupters (GFCIs) should be tested upon each installation and every month thereafter
to ensure proper operation�
Single-phase units are supplied with an internal grounding conductor and/or a grounding-type attachment plug� To reduce the risk
of electrical shock, be certain the unit is properly connected to the Kasco-supplied control panel (refer to the instructions included
with your control panel)�
NEVER run the unit out of the water. This will damage the seals and create a dangerous situation for the operator.
Use extreme caution around water, especially cold water, as in spring, fall, and winter, which poses a hazard in and of itself�
NEVER lift or drag the equipment by the power cords. If you need to pull the unit to the side of the pond, use the anchoring ropes.
Do not use boats that tip easily for installation and follow all boating safety rules and regulations, including wearing a PFD (Person-
al Flotation Device)�
Do not use waders in deep ponds/lakes or ponds/lakes with drop-offs, drastic slopes, or soft bottom material�
Control panels must be installed by a qualified electrician.
Ground Fault Circuit Interrupters (GFCI) should be tested upon each installation and every month thereafter to ensure proper
operation�
For more information regarding your control panel instructions, refer to your control panel owner's manual� A control panel must be
installed a minimum of 5 feet (3m in Canada) from the body of water unless separated from the body of water by a fence, wall, or
other permanent barrier that will make the unit inaccessible to persons in the water� A complete list of control panels can be found
in the
Accessories
Additional Notes
During flotation operation, water is pulled from 360° around and directly below the unit. Keep these areas clear of debris as much as
possible to decrease frequency of screen cleaning�
UNIT SPECS
Operating
Model
Voltage
Amps
3400JF
110-120
7.3
3400HJF
208-240
3.7
4400JF
110-120
11
4400HJF
208-240
5�5
3400 - 4400 J-SERIES FOUNTAIN
section of kascomarine�com�
Locked-Rotor
Control Panel
Amps
Connection
Single-Phase Units
18
C-25 plug in
9
Hardwire C-85
40
C-25 plug in
20
Hardwire C-85
Unit
Connection
Plug into C-25
3400JF
Plug into or
3400HJF /
hardwire C-85
4400HJF
Plug into C-25
4400JF
Plug into or
hardwire C-85
3
Back to Contents
MANUAL
Cord Length
50 ft.
100 ft.
150 ft.
200 ft.
16
14
12
14
14
12
14
12
10
884180 / 2021.1.3
250 -
400 ft.
12
N/A
12
12
10
N/A