Alarm Mode Description - ICP DAS USA ALM-04-MRTU User Manual

Table of Contents

Advertisement

3.3 Alarm Mode Description

Mode 0:
Channel Trigger-General Playback
DI1 to DI4 playback in single independence trigger of 4 channels.
A pulse input triggered the Playback. Playback repeat when the input is not release.
When alarm in playback process, any input trigger will ignore.
The highest DIx channel priority input will take place after the previous playback complete.
Mode 1:
Channel Trigger-Trigger Input priority Playback
DI1 to DI4 playback in single independence trigger of 4 channels.
When alarm in playback process, any trigger input will break & take place the previous
playback.
In this mode, it only playback once, even the input is not release.
Only when multi trigger in same time the highest DIx channel priority will take place
.
ALM-04-MRTU
ALM-04-MRTU User's Manual
Figure 3-8: ALM-04-MRTU Mode 0
Figure 3-9: ALM-04-MRTU Mode 1
User's Manual (Rev1.0, Jan./2020) ------------- 19

Advertisement

Table of Contents
loading

Table of Contents