SMA Solar Technology AG
Result
Meaning/Cause
3005
The maximum length of the
"FI_SMTP Pass" parameter has
exceeded 50 characters.
3006
The maximum length of the
"FI_SMTP FROM" parameter has
exceeded 50 characters.
3007
The maximum length of the
"FI_SMTP TO", "FI_SMTP CC1" or
"FI_SMTP" parameter has
exceeded 50 characters.
3009
The maximum length of the e-mail
subject line has been exceeded.
3011
An e-mail transmission failed and
the precise cause of the failure
could not be determined.
3017
An API command with incorrect
data length was received. Possible
error: ISP or SMTP password does
not exist or is too short.
5001
The modem module failed to
initialize.
5002
The modem did not respond to a
command.
5003
Modem module, not ready (busy).
SBC is trying to send an e-mail while
a dial-up connection to the system
exists. The e-mail will be sent as
soon as the telephone line is free.
5004
Modem module, failed to establish
connection (causes: no physical
connection, bad line quality,
receiver busy or not reachable).
5005
Modem module, connection
terminated by receiver.
5006
Unable to set the MSN for the ISDN
terminal adapter.
Technical Description
Remedy
Check the length of the "FI_SMTP Pass"
parameter. If possible, set the "FI_Function"
parameter to SET SMA SMTP.
Check the length of the "FI_SMTP FROM"
parameter.
Check the lengths of the "FI_SMTP TO",
"FI_SMTP CC1" and "FI_SMTP" parameters.
Update the module to the latest firmware.
If this occurs repeatedly, please contact the
Service Line.
Update the module to the latest firmware.
Update the module to the latest firmware.
Update the module to the latest firmware.
If this occurs repeatedly, please contact the
Service Line.
Check the „FI_ISP Phone No" and the
connection.
Check the connection. Select another ISP user if
necessary.
Check the MSN.
NETPB-TEN081708