5.2 NET Piggy-Back "ISDN" Version

The following basic parameter settings must be made on the Sunny Boy Control / Sunny Boy
Control Plus to enable an incoming and outgoing data link.
Required parameter settings on the device:
CO_NET-ISDN MSN:
-
Telephone number used to receive calls.
CO_NET Auto Answer:
-
Set a value greater than "0" here (recommendation: "2").
FI_ISP Phone No:
-
The access number of your Internet service provider (ISP).
FI_ISP User ID:
-
The user ID that you received from the Internet service provider (ISP).
FI_ISP Password:
-
The password that corresponds to the user ID.
For information on configuring the device for e-mail transmission, see Section 6.

5.3 NET Piggy-Back "GSM" Version

In contrast to landline phones, cellular network providers make a clear distinction between
voice services and data services. For example, they provide
different numbers for voice and data with GSM devices.
A separate data number is required for incoming data connections (access by modem) on the data
logger. This can be requested when arranging the contract with the network provider. Retroactive
activation is also possible via telephone by calling the relevant technical service line and stating the
customer password defined in the contract. If in doubt, please consult your cellular network
provider.
Outgoing data connections from the data logger (access to an Internet service provider) are
possible without an additional data number.
If not just outgoing, but also incoming data connections are to be enabled,
a dedicated data number which operates over the CSD data service is an absolute necessity. Other
data services are not supported. A standard SIM card with additional data connectivity always has
two telephone numbers (multi-numbering).
The GSM data service must be activated.
Please note that the GSM data service must be activated
in your contract. If in doubt, please consult your cellular network provider.
Technical Description
Initial Start-up
NETPB-TEN081708
19