Exception Codes

In case of an error, the BMC drives a blinking code on the blue Status LED (LED1). The same error code is also
reported by the BMC Flags register. The Exception Code is not stored in the Flash Storage and is cleared when the
power is removed. Therefore, a "Clear Exception Code" command is not needed or supported.
5.1.5.

BMC Flags

The BMC Flags register returns the last detected Exception Code since power-up and shows the BIOS in use and
the power mode.
Smart Embedded Management Agent (SEMA)
Exception Code
Error Message
0
NOERROR
2
NO_SUSCLK
3
NO_SLP_S5
4
NO_SLP_S4
5
NO_SLP_S3
6
NO_CB_PWRGD
7
BIOS_FAIL
8
RESET_FAIL
9
RESETIN_FAIL
10
CRITICAL_TEMP
11
POWER_FAIL
12
VOLTAGE_FAIL
13
NO_SYS_GD
14
NO_3V3_A_PGD
15
NO_VDDQ_PG
16
NO_P_5V_3V3_S0_PG
17
NO_1V0_A_PG
18
NO_VCORE_PG

Table 8: SEMA Exception Codes

Bit
Description
[ 0 ~ 4 ]
Exception Code
[ 6 ]
0 = AT mode
1 = ATX mode
[ 7 ]
0 = Standard BIOS
1 = Fail-safe BIOS.

Table 9: SEMA BMC Flags