SECTION 2 – USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION
Overload Sensor Check
Figure 2-2. Overload Sensor
2-10
Check the overload indicator light/alarm to ensure proper
operation. Wedge a block (P/N: ST2741 - located in the
manual storage container) to activate the overload sensor
and keep it activated. Refer to Figure 2-2.
1.
From the Platform Control Console:
a. Confirm an audible alarm sounds.
b. Verify the overload indicator (Red) blinks.
c. Check that all functions are disabled.
2.
From the Ground Control Panel:
a. Confirm an audible alarm sounds.
b. Verify the overload indicator (Red) blinks.
– JLG Lift –
31210313