Item
Output Connector
Type N Standard,
Optional SMA
Operating Temp.
-40 to +140°F
(-40 to +60°C)
Input Power
12 to 24 VDC
@ 120 mA
Power Connector
Coaxial or
PT06E-8-4S
4.2

Power Consumption

The equipment is rated for operation over the range 100 - 240 Volts AC. It has a maximum power
consumption of 60 Watts, and draws a maximum of 600 mA.
4.3

Fuses

The LNA is fitted with two fuses - one each for line and neutral connections. These are contained
within the body of the IEC power inlet connector, behind a small plastic flap.
For 115 and 230 volt AC operation, use T1.25A, 20mm fuses.
4.4

Cables and Connectors

The LNA is shipped with a line inlet cable suitable for use in the country of operation.
If it is necessary to replace this cable, make sure the replacement has an equivalent specification.
Examples of acceptable ratings for the cable include HAR, BASEC and HOXXX-X.
Examples of acceptable connector ratings include VDE, NF-USE, UL, CSA, OVE, CEBEC,
NEMKO, DEMKO, BS1636A, BSI, SETI, IMQ, KEMA-KEUR and SEV.
4.5

Operating Requirements for Regulatory Compliance

To maintain continued compliance with the European Directives:
Make connections to the Tx and Rx IF ports (Type N or Type F connectors using a good
quality coaxial cable - for example 50 Ω or 75 Ω.
Make sure all D type connectors attached to the rear panel have back-shells that provide
continuous metallic shielding. Cable with a continuous outer shield (either foil or braid, or
both) must be used, and the shield must be bonded to the backshell.
Make sure the equipment operates with its cover on at all times. If it becomes necessary
to remove the cover, make sure that the cover is correctly reinstalled before normal
operation resumes.
Specifications
CLNA
(Redundancy)
(Redundancy)
Type N Standard,
Optional SMA
-40 to +140°F
(-40 to +60°C)
12 to 24 VDC
@ 120 mA
Coaxial or
PT06E-8-4S
XLNA
KuLNA
(Redundancy)
Type N Standard,
Optional SMA
-40 to +140°F
(-40 to +60°C)
12 to 24 VDC
@ 120 mA
Coaxial or
PT06E-8-4S
4–2
Low Noise Amplifier Series
Revision 2
KaLNA
(Redundancy)
SMA
-40 to +140°F
(-40 to +60°C)
12 to 24 VDC
@ 120 mA
Coaxial or
PT06E-8-4S
MN-LNAS