8
|
Functions
Option 2: Enter the filter length as a numerical value
If the predefined filter lengths are not suitable, an individual filter length can be entered for the
Moving Average and Moving Median filters. Especially when it comes to applications without dy-
namic changes in distances, such as the verification of the position of an object, a greater filter
length can improve the performance of the sensor. You can specify the length of the Moving Av-
erage and Moving Median filters after selecting the Custom filter.
Moving Median filter: 1 - 21 values
n
Moving Average filter: 1 - 256 values
n
IO-Link parameter: Filter operating mode
Parameter name
Operation Mode.Precision
Filter
MovAvgFilter.Custom Mov-
ing Average Length
MovMedianFilter.Custom
Moving Median Length
26
Values
Standard, High,
Very High, High-
est, Custom
-
-
Operating Manual
Description
Selection among predefined filters
n
(number of measured values per filter).
Custom: Enter the filter length as a nu-
n
merical value.
Freely configurable filter length for Mov-
n
ing Average.
Freely configurable filter length for Mov-
n
ing Median.