1-3. Simple MA Remote Controller [PAC-YT53CRAU], cont.
3 Prepare the bottom case of the remote controller.
4 Connect the remote controller cable to the terminal block on the bottom case.
Peel off the remote controller cable sheath as shown below to connect to the terminal block properly.
Secure the remote controller cable so that the peeled part of the cable will fit into the case.
Sheath
16 (21/32)
6 (1/4)
Unit: mm (in)
Insert the sheathed part of the cable inside
the case, and then secure the cable.
Direct wall installation
• Seal the hole through which the cable is threaded with putty.
To reduce the risk of electric shock, shorting, or
malfunctions, keep wire pieces and sheath shavings
out of the terminal block.
Important
Do not use solderless terminals to connect cables to
the terminal block.
Solderless terminals may come in contact with the
circuit board and cause malfunctions or damage the
controller cover.
Due to continuing improvement, above specification may be subject to change without notice.
32
M-Series - Controls (December 2016)
Top case
Bottom case
Connect the cable.
(non-polarized)
2-core wire must not be
seen on the back.
Remote controller cable
Seal the gap with putty.
Route the cable behind
the remote controller.