1. CONTROLS
1-2. Wired Remote Controller [PAR-32MAA-J], cont.
PEAD-AA5
Function
Enable heater
1st
basic control
1st
Enable heater
Heater
comfort mode
control
2nd
Enable heater
1st
economy mode
1st: Heater output from CN24-1 (yellow) on the indoor unit control board.
2nd: Heater output from CN24-2 (Blue) on the indoor unit control board.
Due to continuing improvement, above specification may be subject to change without notice.
22
Setting
Heater OFF
Inlet air temp.
set temp
Heater ON
Inlet air temp.
set temp - 4.5°F(2.5°C)
•The fan will stop and the heater will turn off when [DEFROST] or [ERROR] is displayed.
Inlet air temp.
Heater output
Heater OFF
Inlet air temp.
set temp
Heater ON
Inlet air temp.
set temp - 1.8°F(1°C)
•The fan will stop and the heater will turn off when [DEFROST] is displayed.
Inlet air temp.
Heater output
Heater OFF
Inlet air temp.
set temp
Heater ON
Inlet air temp.
set temp - 2.7°F(1.5°C)
•The fan will stop and the heater will turn off when [DEFROST] is displayed.
Inlet air temp.
Heater output
Heater OFF
Inlet air temp.
set temp - 1.8°F(1°C)
Heater ON
Inlet air temp.
set temp - 3.6°F(2°C)
•The fan will stop and the heater will turn off when [DEFROST] is displayed.
Inlet air temp.
Heater output
M-Series - Controls (December 2016)
Set temp.
(Room temperature setting)
Set temp. -1.8°F (1°C)
Set temp. -4.5°F (2.5°C)
ON
OFF
Set temp.
(Room temperature setting)
Set temp. -1.8°F (1°C)
ON
OFF
Set temp.
(Room temperature setting)
Set temp. -1.8°F (1°C)
Set temp. -2.7°F (1.5°C)
ON
OFF
Set temp.
(Room temperature setting)
Set temp. -1.8°F (1°C)
Set temp. -4.5°F (2.5°C)
ON
OFF
Mode No.
( )RF thermostat
Initial setting
setup function No.
(Factory setting)
23
11
(123)
(111)
1
-
2
1
2
2
© 2016 Mitsubishi Electric US, Inc.