1. CONTROLS
1-1. System Control
OTHERS
For M Series Indoor Units (New A-control Models Only)
Remote On/Off
1
Operation
• Air conditioner can be started/
stopped remotely.
( 1 and 2 can be used in
combination)
Remote Display of
2
Operation Status
• The On/Off status of air
conditioners can be confirmed
remotely.
( 1 and 2 can be used in
combination)
For M Series Indoor Units (FH series Only)
Interface which outputs
1
the ON/OFF signals
from the air conditioner
to the back-up heater.
(This and MAC333IF-E can be
used in combination)
For P Series and S Series Indoor Units
2-remote Controller
A
Control
With two remote controllers, control
can be performed locally and
remotely from two locations.
Operation Control by
B
Level Signal
Air conditioner can be started/
stopped remotely. In addition,
On/Off operation by local remote
controller can be prohibited/permitted.
Operation Control by
C
Pulse Signal
Remote Display of
D
Operating Status
Operating status can be
displayed at a remote location.
Due to continuing improvement, above specification may be subject to change without notice.
© 2016 Mitsubishi Electric US, Inc.
System Examples
MAC-333IF-E
Switch
Indoor unit
Remote control section
Outdoor unit
(to be purchased locally)
MAC-333IF-E
Resistance
LED
Indoor unit
Outdoor unit
Power supply
Remote moniter section
(to be purchased locally)
System Examples
MAC-1702RA-U
MAC-1710RA-U
Indoor unit
Relay
Outdoor unit
Relay and buck-up heater section
(to be purchased locally)
System Examples
Wired remote controller
Wireless remote controller
PAC-YT53CRAU
PAC-YT53CRAU
PAC-YT53CRAU
* Set "Main" and "Sub"
* When using wired and
remote controllers.
wireless remote controllers
(Example of 1 : 1 system)
(Example of Simultaneous Twin)
Relay box (to be purchased) locally)
Relay box (to be purchased locally)
Adapter for
remote
On/Off
Remote
Remote
control
control
panel
Wired remote
panel
controller
(Example of 1 : 1 system x 2)
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
Relay box (to be purchased) locally)
Connector
cable for
remote
display
Remote
Remote
control
control
panel
Wired remote
panel
controller
(Example of 1 : 1 system x 2)
(Example of 1 : 1 system x 2)
Remote operation adapter/
Remote operation adapter/
Connector cable for remote display +
Connector cable for remote display +
Relay box
Relay box
Remote
Remote
display
display
panel
panel
PAC-YT53CRAU
(Example of 1 : 1 system)
(Example of Simultaneous Twin)
Connection Details
Connect the interface to the air
On/Off operation is possible from
conditioner. Then connect the
a remote location.
locally purchased remote controller
to the terminal in the interface.
Connect the interface to the air
The operation status
conditioner. Then connect the
(On/Off) or error signals can be
locally purchased remote controller
monitored from a remote location.
to the terminal in the interface.
Connection Details
Connect the connector cable to the
It can control the On/Off operation
air conditioner. Then connect the
of buck-up heater.
locally purchased buck-up heater
to the electrical wire of connector
cable.
• Up to two remote controllers can be
connected to one group.
PAR-FL32MA
• Both wired and wireless remote controllers
can be used in combination.
• Operation other than On/Off (e.g., adjust-
ment of temperature, fan speed, and airflow)
Adapter for
remote
can be performed even when remote
On/Off
controller operation is prohibited.
• Timer control is possible with an external
timer.
PAR-FL32MA
• The pulse signal can be turned On/Off.
• Operation/emergency signal can be
Connector
cable for
received at a remote location.
remote
display
PAR-FL32MA
• Operation/emergency signal can be
received at a remote location (when
channeled through the PAC-SF40RM-E
no-voltage signal, when channeled through
the PAC-SA88HA-E
PAR-FL32MA
M-Series - Controls (December 2016)
Control Details
Major Optional Parts Required
• MAC-333IF-E
(Interface)
• Parts for circuit such as relay
box, lead wire, etc. (to be
purchased locally)
• MAC-333IF-E
(Interface)
• Parts for circuit to be
purchased locally (DC power
source needed)
• External power source (12V DC)
is required when using
MAC-333IF-E.
Control Details
Major Optional Parts Required
• MAC-1702/1710RA-U
(Connector Cable)
• Parts for circuit such as relay
box, lead wire, etc.(to be
purchased locally)
Details
Major Optional Parts Required
• Wired Remote Controller
PAC-YT53CRAU
• Wireless Remote Controller
PAR-FL32MA
• Wireless Remote Controller Kit for PCA
PAR-SL93B-E
• Adapter for remote On/Off
PAC-SE55RA-E
• Relay box (to be purchased locally)
• Remote control panel (to be purchased
locally)
• Connector cable for remote display
PAC-SA88HA-E / PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Relay box (to be purchased locally)
• Remote control panel (to be purchased
locally)
• Remote display panel (to be purchased
locally)
• Connector cable for remote display
PAC-SA88HA-E / PAC-725AD
(10 pcs. x PAC-SA88HA-E)
DC 12V signal).
• Relay box (to be purchased locally)
• Remote operation adapter
PAC-SF40RM-E
*Unable to use with wireless remote controller
5