Ambient conditions
Atmospheric pressure
Pollutant concentration
The device has a vapor-permeable valve which gives a certain amount of protection from
condensation inside the device.
7.4.6
Ambient conditions and degree of protection connection box
Ambient conditions
The Connection Box compact CA is specified according to IEC 61131-2 or UL508 as
"Open Type".
Permissible ambient temperature range for transport and storage: -20 to. 60 °C
Permissible ambient temperature range during operation: 0 to. 55 °C
Degree of protection
The degree of protection IP65 is only ensured on the front of the Connection Box compact
CA when the connecting cable or the cover cap is plugged into the connection socket.
Mobile Client900WXN
Operating Instructions, 04/2015, A5E35883103-AB
Permissible range
1.080 to 795 hPa
SO
: < 0.5 ppm;
2
Relative humidity < 60%,
no condensation
H
S: < 0.1 ppm;
2
Relative humidity < 60%,
no condensation
Technical specifications
7.4 Specifications
Comments
Corresponds to an altitude of
-1000 m to 2000 m
Test: 10 cm
/m
; 10 days
3
3
Test: 1 cm
/m
; 10 days
3
3
83