In the "Start Options" dialog, you can specify what is displayed after starting the device:
Entered values, for example, the "Static URL" are retained even after changing the start
option.
Static URL: Address of the website that is called during start. The URL is not checked for
validity. If the website or the web server is unavailable during the start or if no value is
entered, the "Maintenance" website is displayed.
Startupscreen with address field for URL: A page with a URL input field is displayed. The
URL is not checked for validity. If the website or the web server is unavailable during the
start, the "Maintenance" website is displayed.
Customer specific welcome page: The "custom.html" file is looked up in the root directory of
the USB stick, loaded and processed by the browser. The file must not be larger than 1 MB.
An error is displayed if the file is too large. The "Maintenance" website is displayed if an error
occurs.
Server station list: The "stations.conf" file is looked up in the root directory of the USB stick.
● The file must not be larger than 1 MB.
● A maximum of 120 stations is possible.
Syntax and content are checked: An error is displayed if the there are too many stations.
One or more html pages are generated from the "stations.conf" during the next restart. The
"Maintenance" website is displayed if an error occurs.
Mobile Client900WXN
Operating Instructions, 04/2015, A5E35883103-AB
Parameter assignment of a Mobile Client
4.9 "Start Options" page
55