Technical specifications
7.4 Specifications
7.4.2

Technical specifications Connection Box

Weight without packaging
Power supply
Rated voltage
Range, permitted
Transients, maximum permitted
Time between two transients
Cable length between connection box and PLC
Fuse, internal
Current load PLC-accompanying signals
Recovery time
Current consumption without connected HMI device
Current consumption with connected HMI device
Mobile Client900WXN
24 V DC output X10 pin 4 (driver ability)
Protection class and degree of protection
The device meets the requirements of EN 61131-2.
Circuits with rated voltage of V
< 50 V
The device meets the requirements of EN 60529.
Device
side
Front
7.4.3

Technical specifications of the wall-mounting brackets

Wall-mounting bracket, weight without packaging
Magnet wall bracket, weight without packaging
80
Typical
Continuous current, maximum
Inrush current I
t
2
Degree of protection
IP65
Type 4X/Type 12
(indoor use only)
i
Approx. 250 g
+24 V DC
20.4 to 28.8 V (–15%, +20%)
35 V (500 ms)
≥ 50 s
≤ 30 m
Electronic; 1.5 A
< 100 mA
≥ 1 s
< 0.1 mA
Approx. 700 mA
Approx. 850 mA
Approx. 0.6 A
s
2
Signal High: Device connected
(self-limited, max. 100 mA)
Signal Low: Device not connected
Test voltage
500 V AC to other circuits / to ground
Requirements
The connection box has been installed
as described in this document.
Connecting cable or cover cap is
plugged into the socket.
If specified on the rating plate
Approx. 900 g
Approx. 850 g
Operating Instructions, 04/2015, A5E35883103-AB
Mobile Client900WXN

Advertisement

Table of Contents
loading