Download Print this page

Part 7: Specification - Modena Veloce Series User Manual Book

Electric instant water heater
Hide thumbs Also See for Veloce Series:

Advertisement

off and the outlet water is
cold.
The outlet water is cold.
No water flows out from the
shower head.
The temperature of outlet
water is inconsistent
Safety sign is flickering
(EI 2D B)
"ELCB" indicator light is
twinkling flicker (EI 2 W)
 Screen display E1 (EI 2D B)
 "Power" indicator light is
twinkling flicker (EI 2 W)
Model
Rated Voltage / Frequency
Rated Power
Rated Current
Minimum Flow Rate
Water Output Temperature
Working Pressure
Protection Class
IP Rating
Products Size
Color
Temperature Display
Specifications of this appliance may change without notice to improve the quality of the product. Figures in this
manual are schematic and may not match your product exactly. Values stated on the machine labels or in the
documentation accompanying it are obtained in laboratory in accordance with the relevant standards. Depending
on operational and environmental conditions of the appliance, values may vary.
2. PCB error
3. Water flow less than 1.5L/min
4. Impurities clogging the rotor of
water flow switch (water valve)
1. Thermal Cut-out is
disconnected (Screen display
"E3" - EI 2D B)
2. Heating elements is damaged.
1. Water supply is cut off
2. Water inlet valve is not open.
1. The water pressure is unstable
2. The temperature of outlet
water is too high - overheating
protection is working
excessively.
1. Ground damage
2. PCB error.
Electricity leaks
Temperature sensor is broken

Part 7: Specification

EI 2D B
Brown
Yes
11
2. Repair or replace the PCB
3. Increase the water flow
4. Change the flow sensor
5. Open the flow switch and
clean the rotor
1. Press the "Reset" handle of
the Thermal Cut-out after
checking
2. Change the heating elements
1. Wait until the water supply is
restored
2. Open the water inlet valve
Lowering the heating power,
and make the water flow
bigger.
1. Check the grounding
2. Contact MODENA Call center
for repair
Contact MODENA Call center
for repair
Change the temperature
sensor
220V / 50/60Hz
2400W
0~11A
1.5 Liters/minute
30 ~ 55°C
0.03 ~ 0.3 MPa
I
IP25
406 × 232 × 103 mm
EI 2 W
White
No

Advertisement