User Guide
EC-LTS1200-410
Installation
©
Danfoss | July 2021
Cable lug and cable gland assembly cross section
Example of the equipment needed for the assembly
Assembly equipment (example)
2
Assembly example for a 50 mm
cable

Cabling and wiring

Route the power cables as far from the control signal wires as possible. The minimum
separating distance is 100 mm. The crossings must be in an angle of 90º. Power cables and
control wires should be routed near the frame of the application. Make sure that all terminal
connections are tightened correctly.
Install the electric device by the instructions. Make sure that all the applications of the system, for
example, batteries are connected to the electric device by the instructions of this user guide and the
product specific guidelines.
Description
Manufacturer's homepage Art.No./Part No.
Torque key and turnkey
http://www.pflitsch.de
head
Key
http://www.pflitsch.de
Cable with nominal
http://www.hubersuhner.com
2
cross-section of 50 mm
Cable lug
http://www.druseidt.de
Cable gland
http://www.pflitsch.de
Screw
http://www.wuerth.com
Washer
http://www.wuerth.com
Washer
http://www.wuerth.com
730N/10-50
SE30
Radox Elastomer S
03903
Pflitsch blueglobe TRI bg
225ms tri
DIN 912 M8x16 (item:
10285)
DIN 2093, 8,2 x 16 x 0,9
(item: 17332)
DIN 125 D8
(item: 10285)
BC355449988603en-000201 | 31