Chapter 5. Configuration Menu

Unit Menu

5-14
Alarm Format
Sets the alarm format to 13 frames or 16 frames.
Choices: ORB-13, ORB-16
BPV Threshold
Sets the threshold for BPVs to trigger an alarm.
Choices: 10-4, 10-5, 10-6
Exit
This selection will exit to the main configuration menu.
The Unit menu changes the baud rate of the Control In
port and the setup of the Dial Out port. The menu items
are:

Control Port Rate

Sets the baud rate for communication with the PC or
modem.
Choices: 1200, 2400, 9600, 19200, and 38400

Traps

Enables or disables the transmission of trap messages.
Choices: E
and D
NABLE

Access

Sets the method of connection from the TDU 120e to
T-Watch PRO or SNMP.
Choices:
Direct: Used if connected directly to the PC.
Dial: Used when connection is through a modem. The
dial string is entered from T-Watch PRO or SNMP.

Init Modem

Allows you to choose an industry standard or a custom
initialization string for a modem connected to the control
port.
Choices: N
, C
ONE
C
OURIER
TDU 120e User Manual
ISABLE
, H
, M
USTOM
AYES
KBPS
, and USR
OTOROLA
61202156L2-1