Chapter 3. Operation
Step
Position the cursor on the submenu
1
item number and press
Using the space bar, scroll to scan
2
the available value settings.
When the desired value is
3
displayed in the data field position,
press
Select another submenu field or
4
press
submenu.
Data Port Identification
3-4
Edit the Data Field
You can edit data fields preceded by a colon (:). To edit a
data field perform the following steps:
Action
to set that value.
Enter
to return to the
Escape
Exit Any Menu Field Operation or Display
Press
Escape
desired menu level.
When configuring the unit, menu selections will include
options from data port submenus. Selecting data ports is
necessary because the TDU 120e uses a Slot-Port method
to identify the data port the menu item is referencing. If a
module containing a PBX DSX-1 option card with an
Nx56/64 plug-on interface is installed in the option slot,
it would be designated as:
DSX-1 Passthru (1.1)
Where slot=1 and port=1.
The DSX-1 is located in the option slot and is the first port
in that slot.
Nx56/64 (1.2)
Where slot=1 and port=2.
TDU 120e User Manual
The cursor moves to the data
.
field (to the right of the
Enter
submenu item name).
The value settings display
one-at-a-time in the data field
position.
When the value is set, the
cursor moves back to the
submenu item position.
This indicates the operation is
complete.