Appendix A. Understanding SNMP
SNMP MIB Browser Configuration
Step
1
2
3
4
A-6
The following steps are required to configure Network
Manager MIB variable access through the TDU 120e:
Load the desired product MIBs on the network
management station.
Example:
If the administrator is managing TDU 120e and ISU 512
devices, load TDU 120e.MIB, ISU512.MIB, and
RFC1406.MIB.
Create device entries in the NMS database for all units
that are to be managed through the TDU 120e.
The host unit should be configured as the Proxy agent for
the external units. The IP address or host name used for
the proxy designation is that of the TDU 120e.
Set community names in the device's entries for external
units to the TDU 120e community name with the device
Unit ID appended.
See TDU 120e SNMP ACCESS on page A-4 for more
information.
Set the device timeout for all device entries in the NMS
device database to five seconds, including the host unit.
TDU 120e User Manual
Action
61202156L2-1