Cellular Modem Modules
6.8 RUGGEDCOM RX1500PN LM W61
Conducted Rx (Receive) Sensitivity for CDMA Frequency Bands
Band Class 0
Band Class 1
Band Class
10
Conducted Tx (Transmit) Maximum Output Power Tolerances for LTE Frequency
Bands
Band 4
Band 13
Band 25
Conducted Tx (Transmit) Maximum Output Power Tolerances for CDMA
Frequency Bands
Band Class 0
Band Class 1
Band Class 10
Operating Temperature
Certification
This module has been certified to comply with the requirements of the following
standards.
174
Band
Standard
CDMA 1X
EVDO
CDMA 1X
EVDO
CDMA 1X
EVDO
Band
23 + 2.7/1.7 dB
23 + 2.7/1.7 dB
23 +2.7 dB
Band
Operating Temperature
-30 to 70 °C (-22 to 158 °F)
-40 to 85 °C (-40 to 185 °F)
LImit (dBm)
Room
Typical
(dBm)
-104
-108
-105.5
-109.5
-104
-109
-105.5
-109.5
-104
-108.5
-105.5
-109.5
LImit (dBm)
Room Typical (dBm)
23 ± 1 dB
23 ± 1 dB
23 ± 1 dB
Room (dBm)
24 ± 1 dB
24 ± 1 dB
24 ± 1 dB
Class A (3GPP Compliant)
Class B (Operational, Non-3GPP Compliant)
Class A (dBm)
Extreme
Limit
-107
-106.5
-108.5
-108
-108
-107.5
-109
-108
-108
-107.5
-109
-108
Class A Extreme (dBm)
23 ± 1 dB
23 ± 1 dB
23 ± 1 dB
Class A Extreme (dBm)
24 ± 1 dB
24 ± 1 dB
24 ± 1 dB
Compliance
Catalog, 07/2021, C79000-G8976-1320-16
Notes
CDMA 1 x
0.5% FER,
SO2
EVDO rev A
0.5% PER,
DRC4
CDMA 1 x
0.5% FER,
SO2
EVDO rev A
0.5% PER,
DRC4
CDMA 1 x
0.5% FER,
SO2
EVDO rev A
0.5% PER,
DRC4
RUGGEDCOM Modules