timeout is more than 1 minute, BMC will reset.
When entering the flash mode, set watchdog time to 20 mins, if timeout BMC will reset
automatically. When flashing image starts, the watchdog will update to 20 mins, if timeout
BMC will reset automatically.
8.12.2 Software Watchdog
BMC regularly detects the working status of internal services. When the progress is
abnormal, BMC will restart the corresponding service:
IPMI Server
KVM Server
Virtual Media Server

8.13 LED

The system provides LEDs to indicate the health of the system.
Table 8-28 LEDs Indicating the Health of the System
LED name
SYS LED
SYS LED
SYS LED
Power LED
Power LED
BMC Heartbeat
BMC Heartbeat
DIMM Error
PSU Error
FAN Error
CPU Hot

8.14 BMC Network

8.14.1 LAN Interface
BMC usually supports an LAN controller dedicated to BMC and an LAN controller shared for
Color
Status
Description
1.When system is off, SYS LED is OFF.
Red
OFF
2.System works fine, SYS LED is OFF.
The following CPU events occur:
1. CPU IERR
Red
ON
2. CPU Thermal Trip
3.
The following warning about CPU appears:
Red
BLINK
Processor Automatically Throttled
Yellow
ON
Power plugged in, but not powered on
1. Power on
Green
ON
2. Power button is pressed
Green
BLINK
BMC status OK
Green
ON/OFF
BMC error
Red
ON
DIMM ECC or uncorrectable ECC occurred
Red
ON
PSU sensors error
Red
ON
Fan sensors error
Red
ON
CPU Proc Hot PIN detected
PCIE Error