Direct Drive tapping unit with touch screen multiple control panel

INSTALLING:

1- Place the tapping unit and align it carefully to the hole. Secure it in position with 4 screws and 2 pins (see dimensions and
position on pages 18-19-20)
INsTALLINg
2- Connect the tapping unit socket into the plug D ( fig.1) of the control panel. The serial number of the tapping unit and serial
number of the panel must be the same. The serial number is printed on the back of the tapping unit and on the right side of the
1.
Place the tapping unit and align it carefully to the hole. Secure it in position with 4 screws and 2 pins (see dimensions
panel.
3- Connect the compressed air to the panel with a 6 mm pipe (E - fig. 1).
and position on pages 26-27-28);
The air pressure should be as follows:
2.
Connect the tapping unit socket into the plug E (FIG. 1) of the control panel. The serial number of the tapping unit and
M2 = 2 bar
serial number of the panel must be the same. The serial number is printed on the back of the tapping unit and on the
M3- M4 = 3 bar
right side of the panel.
M5- M6 = 4 bar
3.
Connect the compressed air to the panel with a 8 mm pipe (F - FIG. 1). The air pressure should be as follows:
M8 or bigger= 5-6 BAR
M2 = 2 BAR
4- Make wire connections on socket C (fig. 1):
alarm to the press, end of cycle signal, external emergency system
M3 - M4 = 3 BAR
attached to this manual
M5 - M6 = 4 BAR
5-
Connect the control panel to power supply 230 V AC 50-60 Hz
M8 or bigger= 5-6 BAR
4.
Make wire connections on socket D (FIG. 1): start signal and other desired connectios such as: electrovalve for
lubrication, alarm to the press, end of cycle signal, external emergency system. Follow instructions on pages 13-
23-33-43 of the wiring diagram attached to this manual;
5.
Connect the control panel to power supply 400 V AC 50-60 Hz.
NEVER CONNECT PANEL AND TAPPING
UNIT WITH DIFFERENT SERIAL NUMBER!
NEVER CONNECT PANEL AND TAPPING UNIT
WITH DIFFERENT SERIAL NUMBER!

ACCESSING FUNCTIONS WITH A PASSWORD

ACCEssINg FUNCTIONs wITH A PAsswOrD
The touch screen on the panel may display a locked or unlocked padlock (fig. 6).
By pressing on this symbol the operator will see a page designed to enter
The touch screen on the panel may display a locked or unlocked padlock (FIG. 6). By
passwords which allow access to some functions (fig.4).
pressing on this symbol the operator will see a page designed to enter passwords
USER, SUPER USER, OPTIONALS and MAINTENANCE boxes (fig.4) will
which allow access to some functions (FIG. 4).
change colour from grey to green according to the entered passsword and
USER, SUPER USER, OPTIONALS and MAINTENANCE boxes (FIG. 4) will change
enabled functions. See following table 1
colour from grey to green according to the entered passsword and enabled
functions. See following TABLE 1.
USER
On
USER
Off
SUPERUSER
On
SUPERUSER
Off
OPTIONALS
On
OPTIONALS
Off
MAINTENANCE
On
MAINTENANCE
Off
ATTENTION: Access to SET UP and SERVICE menu, which will be explained in the following paragraphs, requires the
* Super User password can be modified following instructions on page 12
padlock to be unlocked by password 1234.
Manufaturer recommends locking the padlock again using password 1111, after setting the threading program.
ATTENTION! Access to sET UP and sErVICE menu, which will be explained in the following paragraphs, requires
the padlock to be unlocked by password 1234.
Manufaturer recommends locking the padlock again using password 1111, after setting the threading program.
Start signa
l and other desired connectios such as:
PASSWORD
PADLOCK
PAsswOrD
PADLOCk
on
1111
off
1111
on
1234
off
12345*
upon
on
reques t
off
upon
request
not
on
off
a va i l a bl e
not
available
. Follow instructions on pag. 4 of the wiring diagram
FUNCTIONS
FUNCTIONs
ON/OFF
CHANGE OF TAP
Change of tap
SET UP
SERVICE
RIGHT-LEFT THREADING
THREAD CHECKER (D-TC)
Right-left threading
AUTOMATIC PRESSURE REGULATOR (D-APR)
Thread checker (D-TC)
STORAGE USB KEY (D-USB)
Automatic pressure regulator (D-APR)
RETURN SPEED
Storage usb key (D-USB)
MAINTENANCE
Return speed
(MANUFACTURER ONLY)
Maintenance (manufacturer only)
4
electrovalve for lubrication ,
serial n°
serial nr.
SUPER
OPTIO
USER
NALS
0
Fig. 4
FiG. 4
On/off
Set up
Service
table1
taBlE 1
4