6.3
In-Panel NEO
Device
Bit Address
C00000.00-C00006.31
C00100.00-C00106.31
C10000.00-C10019.31
C10100.00-C10119.31
Variable
C30000.00-C3003E.31
*1
Areas
C30100.00-C3013E.31
C50000.00-C50000.31
C50100.00-C50100.31
C70000.00-C70001.31
C70100.00-C70101.31
Operation
command
*6
*1
Available variable area range varies depending on the using Temperature Controller. Refer to the manual of
OMRON Temperature Controller for setting.
*2
When you write the bit address, the Display reads the word address corresponding to that of the External Device
first. Then, it changes the target bit address among the word data once read and returns the word data to the
External Device. Note that the correct data may not be written if you change the word address value in the ladder
program while the Display reads the data of the External Device and returns it to the External Device.
*3
Write disable
*4
When writing, switch the setting area of the Temperature Controller to setting area 1.
*5
Read disable
*6
When executing the operation command (write), specify the directive code for the device address. Set the
related information for the writing value. Set the related information in hexadecimal number, such as 0x00,
0x01. Set the device code to be used in the painting software as A, and enter each command code instead of the
device address.
Command code list
Command
code
"00" or "10":OFF(disabled)
00
"01" or "11":ON(enabled)
"00": Run CH1
"01": StopCH1
"10": Run CH2
01
"11": Stop CH2
"F0": Run CH1, CH2
"F1": Stop CH1, CH2
"00": Select target value 0 for CH1
"01": Select target value 1 for CH1
"10": Select target value 0 for CH2
02
"11": Select target value 1 for CH2
"F0": Select target value 0 for CH1, CH2
"F1": Select target value 1 for CH1, CH2
GP-Pro EX Device/PLC Connection Manual
Word Address
C00000-C00006
C00100-C00106
C10000-C10019
C10100-C10119
C30000-C3003E
C30100-C3013E
C70000-C70001
C70100-C70101
-
A0000-A000C
Related information
*1
*1
Temperature Controller CompoWay/F Driver
This address can be specified as system data area.
32bit
C50000
C50100
* 2
Command comment
Communication writing
Run/Stop
Multi-SP
*1
*1
43
Remarks
*2*3
Double Word Device
*2
Double Word Device
*2 *4
Double Word Device
*2
Double Word Device
*2*4
Double Word Device
*5
Word Device
Device address
A0000
A0001
A0002
continued to next page