Nortel CallPilot 1001rp Installation And Configuration Manual page 241

Maintenance and diagnostics
Hide thumbs Also See for CallPilot 1001rp:
Table of Contents

Advertisement

October 2002
To check the consistency of the system drives
You must verify that each pair of drives is correctly synchronized before
continuing with the RAID splitting procedure. To verify that the drives are
correctly synchronized, use the DAC Administration Utility to run a
consistency check on each system drive that is configured, as follows:
1 In the DAC Administration Utility window, select Management
Consistency Check.
Result: The Consistency Check dialog box appears. Each system drive
(Sys Drv) represents a mirrored pair of hard drives.
2 Click Sys Drv 0 to initiate a consistency check on the system drive.
Result: The system prompts you to select what should be done if
inconsistent data is found on the system drive.
Part 5: 1001rp Server Maintenance and Diagnostics
Performing RAID maintenance
241