Replacing basic chassis components
To replace the alarm board
1 Power off the server.
2 Loosen the two thumbscrews securing the faceplate to the left of the
1001rp server power supply modules (see "A" in the diagram below).
If needed, use a flat-blade screwdriver. The thumbscrew must rotate
freely and not contact the chassis threads.
3 Pull the carrier free from the chassis (see "B" in the diagram above).
4 The alarm board is secured to the carrier by two Phillips-head screws.
Remove the defective alarm board from the carrier.
5 Secure the replacement alarm board to the carrier using two Phillips-
head screws.
6 Align the carrier with the chassis and slide the board into the chassis.
Note: The card encounters some resistance as it meets the connector.
7 Tighten the thumbscrews to secure the faceplate to the chassis.
144
A
B
Standard 1.0
G101729