Bosch rexroth HS5E Instruction Manual page 70

For axial piston variable pump a4vso, a4vbo, a4vsg and a4csg
Table of Contents

Advertisement

70/104
A4... with HS5E(V)(L) control system Series 1x and 30 | Commissioning
For applications in the
open circuit A4VSO and
A4VBO
For applications in the
closed circuit A4VSG and
A4CSG
Bosch Rexroth AG, RE 92076-01-B/2021-04-22
8.1.5.1 Setting pressure sensors, voltage, or current interface X2M1, X2M2
(analog inputs/outputs)
Fig. 23: Setting of pressure sensors, voltage points or interfaces
8.1.5.2 Settings of pressure transducer
With applications in an open circuit, it can be an advantage to be able to switch
between several pressure transducers. The HS5E pilot control valve gives you the
option of connecting two pressure transducers. For this, you must configure two
assignments for the corresponding analog inputs with destination actual pressure
value 1 (P-0-2940) and actual pressure value 2 (P-0-2941). The assignment with
destination actual pressure value 1 must always be present, since an A4Vx O
with HS5E(V)(L) control system always needs one valid actual pressure value for
control. Refer to chapter 7.6.8 on page 61 for the various options for connecting
a pressure transducer.
For applications in the closed circuit, two pressure transducers are required.
The HS5E pilot control valve gives you the option of connecting two pressure
transducers. For this, you must configure two assignments for the corresponding
analog inputs with destination actual pressure value A (S-0-0803) and actual

Advertisement