Commissioning | A4... with HS5E(V)(L) control system Series 1x and 30
▶ After the running-in phase, have a hydraulic fluid sample analyzed for the required
cleanliness level.
▶ Change the hydraulic fluid if the required cleanliness level is not reached.
If a laboratory test is not carried out after the running-in phase, it is
recommended to change the hydraulic fluid.
8.3 Recommissioning after standstill
Depending on the installation conditions and ambient conditions, changes may occur
in the system which make recommissioning necessary.
The following criteria may make recommissioning necessary:
• Air in the hydraulic system
• Water in the hydraulic system
• Old hydraulic fluid
• Other contamination
▶ For recommissioning, proceed as described in chapter 8.1 "Initial commissioning"
on page 65.
RE 92076-01-B/2021-04-22, Bosch Rexroth AG
83/104