A4... with HS5E(V)(L) control system Series 1x and 30 | Commissioning
Bosch Rexroth AG, RE 92076-01-B/2021-04-22
Fig. 22: Connection selection
By clicking on the OK pushbutton, you can now establish a connection to the
selected system.
If EtherCat or VARAN are activated as the fieldbus system, you can deactivate
them for direct communication with IndraWorks. To do this, click on the
EtherCAT/VARAN Deactivation pushbutton to send the deactivation command. As
an alternative with these bus systems, it is possible to access the HS5E pilot
control valve via the control's engineering port.
It is advisable to have a second Ethernet port on your PC or laptop for parallel
operation of the Internet, for example.

8.1.5 Making the basic setting on the control electronics

You must have installed the IndraWorks engineering tool to be able to set the control
electronics. Users must configure the HS5E(V)(L) control system to match customer-
specific requirements. This mainly affects the following settings:
• As-delivered, the command value specification is analog.
When using BUS, you must make the corresponding master communication setting.
• Pressure acquisition settings (only with HS5E(V)(L), not HS5E(V)(L)P if using the
pressure transducer included in the scope of delivery)
• Setting of torque limitation
• Controller optimization (see chapter 8.1.7 "Setting controller parameters" on
page 76 or also refer to the additional information in data sheet 30237-Z).