<Operation>
1. Press the SET button in measurement mode to display set values.
(The item to be changed is displayed on the sub display)
Set value on the right side of the sub screen flashes.
2. Press the UP or DOWN button to change the set value.
The UP button is to increase and the DOWN button is to decrease the set value.
Press the UP button once to increase by one digit, or press and hold to continuously increase.
Press the DOWN button once to decrease by one digit, or press and hold to continuously decrease.
3. Press the SET button to finish the setting.
: The above example is for the 500 L/min type.
: For models with switch outputs for both OUT1 and OUT2, [P_2] or [n_2] will be displayed too. Set as above.
: For input of hysteresis, perform the settings referring to [F 1] Setting of OUT1 (page
: When a mode other than hysteresis mode is selected, "Input of set value" of page
: Note that the set value and hysteresis are limited by each other.
: For more detailed settings, set each function in function selection mode (page 30).
35
to) and [F 2] Setting of OUT2 (page
36
is displayed.
-28-
42
to).
No.PF※※-OMY0002