LG MASTER-K Series User Manual page 59

Programmable logic controller
Table of Contents

Advertisement

Chapter 5.
GM PROGRAMMING
● Operation Description
The motor for moving the cart rotates with start command, and makes the cart stop at the first stop
position with the High-speed counting module counting the encoder signals from the motor.
Then, if the first work complete signal turns ON, the motor moves the cart to stop at the second stop
position. When the second work complete signal turns on, the motor return the cart to the start position.
● I n p u t / O u t p u t S i g n a l A l l o c a t i o n
% I0.0.0 : Start Command
% I0.0.1 : 1st Work Complete Signal
% I0.0.2 : 2nd Work Complete Signal
%Q0.1.0 : Motor forward rotation signal (On : forward rotation , Off : Stop)
%Q0.1.1 : Motor reverse rotation Signal (On : Backward rotation, Off : Stop)
%Q0.1.16 - % Q0.1.31 : Indicates the current count value(BCD) of
Driving mode
Motor
Forward
rotation
Start position
Motor
reverse
rotation
*1. 100(Difference between stop position and speed reducing position) is an interval
delayed by reducing timing of the inverter.
the High-speed counting module.
Speed reducing position
First stop position
Speed reducing position
Input
5 - 14
Output
Speed reducing position
D(pulse)
Second stop position

Hide quick links: