Chapter 6. BUFFER MEMORY AND I/O SIGNAL CONFIGURATON
③ Counter operation enable signal
This signal should be turned On in order that the high speed counting module start counting by
the pulse input. If this signal turns Off, the high speed counting module does not execute counting.
④ Increment/decrement count specification signal
When the increment/decrement mode is the program mode at 1-phase pulse inputs, Decrement
count will be proceeded if this signal is turned On. Increment count if Off. ( See 5) of section
4.2 )
⑤ Output enable signal
Turn this signal On to allow the terminal block(or external connector) output signals (OUT1 and
OUT2) to be outputed.
⑥ Home Latch enable signal
If this signal is turned On and phase Z and L/S inputs turns On, then the Home input signal turns
On and the current value will be reset(000000).
⑦ Coincidence Reset Signal
Turns this signal On to reset the signal ' current value = set value' .
⑧ Carry/Borrow Reset Signal
When a Carry or Borrow signal has occurred, this signal is used to reset it.