Shutdown; Maintenance - Graco FOAM-CAT 400 SPRAYER Instructions Manual

Air powered, bulldog pump, 240 volt, 1 or 3 phase, 50/60 hz
Table of Contents

Advertisement

Operation - General Startup Instructions
8. Adjust the gun's clean-off air.
WARNING
INJECTION HAZARD
To reduce the risk of an injection injury,
always follow the items in Step 8 care-
fully before adjusting the clean-off air.
a. Lock the trigger safety (40).
b. Close the needle valves (64).
c. Unlock the trigger safety.
d. Trigger the gun to relieve the fluid pressure.
e. Lock the trigger safety again. See Fig. 10.
f.
Using a hex key wrench (71), screw in the
setscrew (72) of the clean-out hole until no air
or almost no air is escaping. See Fig. 10.
g. Regulate the air to the gun to 100 psi (0.7
MPa, 7 bar).
h. Back off the setscrew two turns as a test setting.
i.
If the air appears to affect the spray pattern,
screw in the setscrew another turn. If build up
behind the air cap occurs, back off the set-
screw about 1/2 turn at a time.
71
RES
64
Fig. 20
78
40
04457
II .

Shutdown

WARNING
INJECTION HAZARD
To reduce the risk of a serious injury,
always follow the Pressure Relief
Procedure on page 15 whenever you
are instructed to relieve the pressure.
1. At the end of each work day, stop the pump with
the displacement rod in the down position.
2. Shut off the heat and main circuit breakers and
relieve the fluid pressure.
3. Disconnect the gun from the fluid manifold, flush
the gun as instructed in manual 307546, and store
the gun.
III . Maintenance
Keep the displacement pump packing nut 2/3 full of
IPO at all times to help protect the pump packings.
CAUTION
Trace amounts of IPO may get into the foam. Before
using the IPO make sure that it will not affect the
development and appearance of the foam.
See the separate instruction manual for each system
component for routine maintenance and repair proce-
dures.
308144
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

224546

Table of Contents