Advertisement

Quick Links

RIS 12002200 V EKO 3.0
EN
MOUNTING AND INSTALLATION INSTRUCTION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RIS V EKO 3.0 1200VEL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Salda RIS V EKO 3.0 1200VEL

  • Page 1 RIS 12002200 V EKO 3.0 MOUNTING AND INSTALLATION INSTRUCTION...
  • Page 2: Table Of Contents

    1. CONTENT 2. SYMBOLS AND MARKING 3. SAFETY INSTRUCTIONS AND PRECAUTIONS 4. INFORMATION ABOUT THE PRODUCT 4.1. DESCRIPTION 4.2. DIMENSIONS AND WEIGHT 4.3. TECHNICAL DATA 4.4. OPERATING CONDITIONS 4.5. STANDART PACKAGE OF COMPONENTS 4.6. DESCRIPTION OF COMPONENTS 5. INSTALLATION 5.1. RECEPTION OF GOODS 5.2.
  • Page 3: Symbols And Marking

    2. SYMBOLS AND MARKING Warning – pay attention Additional information Apply the auxiliary label on the unit (on an easily accessible location) or on the dashed location of the technical manual in order to keep the im- portant information about the unit. Figure.
  • Page 4: Safety Instructions And Precautions

    3. SAFETY INSTRUCTIONS AND PRECAUTIONS Read these instructions very carefully before installing and using this equipment. Installation, connection and maintenance should be carried out Main safety rules Danger • of the device have stopped. • Make sure that the fans are not accessible through air ducts or branch openings. •...
  • Page 5: Information About The Product

    4. INFORMATION ABOUT THE PRODUCT 4.1. DESCRIPTION Not suitable for operation in pools, saunas and other similar premises. 4.2. DIMENSIONS AND WEIGHT RIS 1200-2200 V EKO 3.0 v2020.1 EN |...
  • Page 6 1200 1200 1200 1200 1900 1900 1900 1900 2200 2200 2200 2200 RIS EKO 3.0 [mm] 1350 1350 1350 1350 2000 2000 2000 2000 2000 2000 2000 2000 [mm] [mm] 1200 1200 1200 1200 1600 1600 1600 1600 1600 1600 1600 1600 [mm]...
  • Page 7: Technical Data

    4.3. TECHNICAL DATA RIS EKO 3.0 1200VE 1200VW 1900VE 1900VW 2200VE 2200VW Exhaust air fan phase/voltage [50 Hz/VAC] 1/230 1/230 1/230 1/230 1/230 1/230 [kW/A] 0,38/2,5 0,38/2,5 0,47/2,04 0,47/2,04 0,715/3,1 0,715/3,1 speed [min 3370 3370 2530 2530 2800 2800 control input [VDC] 0-10 0-10...
  • Page 8: Description Of Components

    4.6. DESCRIPTION OF COMPONENTS 1 - Plate heat exchanger; 2 - Supply fan; 3 - Exhaust fan; 4 - By-pass damper | EN RIS 1200-2200 V EKO 3.0 v2020.1...
  • Page 9: Installation

    5. INSTALLATION 5.1. RECEPTION OF GOODS Each device is carefully checked before transportation. When receiving the goods, checking the devices for any damage made during transporta- tion is recommended. If any damage to the unit is observed, immediately contact the representatives of a transport company. Please inform the representative of the manufacturer, if any deviation of the device is noticed.
  • Page 10: Unpacking

    Figure 5.2.2. Lifting 5.3. UNPACKING Accessories may be packed together with the product. Prior to transporting the unit, the accessories should be unpacked • • • • • Before commencing the installation of the unit, please check if all ordered equipment have been delivered. Any variation from the ordered equip- ment list must be reported to the product supplier.
  • Page 11: Piping And Instrumentation Diagram

    5.4. PIPING AND INSTRUMENTATION DIAGRAM Figure. 5.1. * KE1 - only in electrical version; * KV1 - used in water version; ** Possible to control. THE LIST OF COMPONENTS Plate heat exchanger Supply air fan Exhaust fan Exhaust air temperature sensor Supply air temperature sensor Extract air temperature and humidity sensor CO2 sensor...
  • Page 12: Mounting

    POSIBLE PCB INPUTS/OUTPUTS Fire alarm Alarm indication output Working indication output 5.5. MOUNTING • • When connecting air ducts, consider the labels on the casing of the unit. • Before connecting to the air duct system, the connection openings of ventilation unit should be closed. •...
  • Page 13: Drainage

    • Install the supporting legs. • The units are assembled from separate sections. • • 5.7.1. DRAINAGE 5.8. CONNECTION OF THE AIR DUCT • • • and noise level, you can increase the diameter. • In order to reduce the level of the noise in the air supply system, install dampers (see the chapter on air supply system installation). •...
  • Page 14: Start-Up Recommendations

    • made during transportation. • The manufacturer does not assume any liability for personal injuries and property damage due to nonconformance with the provided instructions. 5.10. START-UP RECOMMENDATIONS 5.10.1. SYSTEM PROTECTION RIS EKO 3.0 1200VE 1200VW 1900VE 1900VW 2200VE 2200VW F1(Q2) F2(Q3) RIS EKO 3.0...
  • Page 15: Maintenance

    6. MAINTENANCE 6.1. SAFETY INSTRUCTIONS Unplug the unit from the mains before opening the door (disconnect the power plug from the outlet or in case a automatic circuit breaker installed, disconnect it as well. Make sure that it cannot be turned on by third parties) and wait until the fans completely stop (for about 2 min.).
  • Page 16: Filters Maintenance

    6.4. FILTERS MAINTENANCE direction. tion manual or on our website www.salda.lt 6.5. FANS MAINTENANCE • • The fan should be inspected and cleaned at least once per year. • • Proceed to maintenance and repair after any fan rotation is stopped.
  • Page 17: Heater Maintenance

    6.7. HEATER MAINTENANCE • • • • • If necessary, electric heater can be removed. Disconnect the electrical connector from the heater and remove the heater. 6.8. CONTROL BOARD MAINTENANCE • • Open the cover of the product. • • Remove the control box cover. •...
  • Page 18: Control

    BMS over Modbus TCP/IP FLEX BMS over BACnet TCP/IP 7.2. DEVICE FUNCTIONS WEB application and SALDA AIR mobile application. Refer to the instruction manual of the existing control device for unit control instructions. | EN RIS 1200-2200 V EKO 3.0 v2020.1...
  • Page 19: Accessories

    8. ACCESSORIES RIS EKO 3.0 1200VE 1200VW 1900VE 1900VW 2200VE 2200VW LSVF 315 FIT000308 FIT000308 Flexible connec- LSVF 400 FIT000310 FIT000310 FIT000310 FIT000310 tion VVP45.10-0.63 ACC000140 Valves VXP45.10-0.63 ACC000143 AVA 315 ACC000194 ACC000194 AVA 400 ACC000195 ACC000195 ACC000195 ACC000195 AVA-DX 315 ACC000148 ACC000148 Heaters/...
  • Page 20 Actuator for damper ACC000311 ACC000311 LM230A-TP Actuator for damper ACC000309 LF230 SM230A-TP ACC000315 ACC000315 ACC000315 ACC000315 Actuators NF230A ACC000313 ACC000313 ACC000317 ACC000317 ACC000317 valve SSB61 200 Nm ACC000318 ACC000318 ACC000318 ACC000318 ACC000318 ACC000318 valve SSB81 200 Nm EKA NV 315-1.0-1f ACC003906 ACC003906 EKA NV 315-1.2-1f...
  • Page 21: Connection Of Accessories

    Filter set RIS 1200 V EKO 3.0 (ePM10- ACC004881 ACC004881 50+ePM1-70-2pcs.) Filter sets Filter set RIS 1900 H/V EKO 3.0 (ePM10- ACC004886 ACC004886 ACC004886 ACC004886 50+ePM1-70-2pcs.) 8.1. CONNECTION OF ACCESSORIES 8.1.1. FIRE PROTECTION SIGNAL INPUT (FIRE PROTECTION INPUT (NC)) 8.1.2. EXTERNAL CO /PRESSURE SENSORS Sensors connection:...
  • Page 22: Co2 Concentration According To Pettenkofer Limit

    If the duct CO2 transmitter is used, it must be installed in the extract air duct. To install duct transmitters, hole drilling tools are required . 8.1.4. CO2 CONCENTRATION ACCORDING TO PETTENKOFER LIMIT 8.1.5. CONNECTION OF SUPPLY AND EXTRACT AIR DAMPERS ators.
  • Page 23: Connection Of Remote Control Panel Or Modbus

    8.1.6. CONNECTION OF REMOTE CONTROL PANEL OR MODBUS 8.1.7. WATER HEATER CIRCULATION PUMP AND VALVE ACTUATOR 3.0 units). Wiring diagram RIS 1200-2200 V EKO 3.0 v2020.1 EN |...
  • Page 24: Recommended Scheme For Connection Of Internal And External Components

    8.1.8. RECOMMENDED SCHEME FOR CONNECTION OF INTERNAL AND EXTERNAL COMPONENTS Figure 8.1.8.1. | EN RIS 1200-2200 V EKO 3.0 v2020.1...
  • Page 25 Figure 8.1.8.2. RIS 1200-2200 V EKO 3.0 v2020.1 EN |...
  • Page 26: Possible Faults And Troubleshooting

    9. POSSIBLE FAULTS AND TROUBLESHOOTING FAILURE CAUSE EXPLANATION / CORRECTIVE ACTIONS No supply voltage Unit is not operating leakage relay is active (if installed by the installer) matic protection Check if fans are rotating Air supply heater or pre-heater is not operat- ing or malfunctioning (if installed) Manual safety device is activated MUST be contacted to identify and eliminate...
  • Page 27: Ecodesign Data Table

    10. ECODESIGN DATA TABLE RIS EKO 3.0 1200 VE 1200 VW Declared typology bidirectional bidirectional Type of drive Variable Variable Type of HRS recuperative recuperative 83,8 83,8 /s ] 0,33 0,33 [ kW ] 0,81 0,81 SFPint [ W/(m /s) ] 1203 1203 Face velocity...
  • Page 28 2200 VE 2200 VW RIS EKO 3.0 Declared typology bidirectional bidirectional Type of drive Variable Variable Type of HRS recuperative recuperative 82,8 82,8 /s ] 0,57 0,57 [ kW ] 1,32 1,32 SFPint [ W/(m /s) ] 1295 1295 Face velocity [ m/s ] Normal external pressure [ Pa ]...
  • Page 29: Declaration Of Confimity

    11. DECLARATION OF CONFIMITY Manufacturer SALDA, UAB LT-78109 Šiauliai, Lithuania Tel.: +370 41 540415 www.salda.lt RIS * EKO 3.0 Machinery Directive 2006/42/EC EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU Ecodesign Directive 2009/125/EC RoHS 2 Directive 2011/65/EU Ecodesign requirements for ventilation units Nr. 1253/2014 Energy labeling of residential units Nr.
  • Page 30: Warranty

    12. WARRANTY date. such damage. damaged by installing the control system. 4.1. mechanical damage; 4.2. damage caused by entering outside objects, materials, liquids; lation and mounting regulations, deliberate or careless users or third-party behavior. days and deliver the equipment to manufacturer. Delivery costs should be covered by customer. Manufacturer reserves the right to change this technical passport any time without prior notice, if some typographic errors or inaccurate information is found, as well as after improving the apps and/or the devices.
  • Page 31 RIS 1200-2200 V EKO 3.0 v2020.1...
  • Page 32 Look at the product label. ** - At least. NOTE. The customer shall be required to complete the Product Maintenance Table. MANUALS IN OTHER LANGUAGES https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ MAN000343 Ragainės g. 100 +370 41 540 415 Šiauliai LT-78109, LITHUANIA...