You will need:
A location allowing for proper exhaust installation.
See "Venting Requirements."
A separate 30 amp circuit for electric dryers.
A separate 15 or 20 amp circuit for gas dryers.
If you are using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
A sturdy floor to support dryer and a total weight (dryer
and load) of 200 lbs. (90.7 kg). The combined weight of
a companion appliance should also be considered.
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C).
At lower temperatures, the dryer might not shut off at the end
of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
Installation clearances:
The location must be large enough to allow the dryer door to open
fully.
Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Dryer Dimensions
(686 mm)
6
27"
43"
(1092 mm)
1
"
/
1
2
(38 mm)
22
/
"
29
"
3
/
1
4
2
(578 mm)
(749 mm)
A. Wide opening side-swing door
B. Wide opening hamper door
Installation Spacing
18"*
(457 mm)
27"
1"
1"
(686 mm)
(25 mm)
(25 mm)
(25 mm)
A
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
*Required spacing
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of installation
and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Mobile home – Additional installation requirements
This dryer is suitable for mobile home installations. The installation
must conform to the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard
for Mobile Home Construction and Safety, Title 24, HUD Part 280)
or the Canadian Manufactured Home Standard CAN/CSA-Z240
MH.
Metal exhaust system hardware, available for purchase. For
further information, please reference the "Assistance or Service"
section of the Use and Care Guide.
Special provisions must be made in mobile homes to introduce
outside air into the dryer. The opening (such as a nearby
window) should be at least twice as large as the dryer exhaust
opening.
13
/
"
3
4
(349 mm)
29
(749 mm)
14" max.*
48 in.
2
*
(356 mm)
2
(310 cm )
*
2
24 in.
2
(155 cm )
1"*
29
5
½"
½"*
(749 mm)
(140 mm)
B
C
/
"
1
2
3"*
(76 mm)
3"*
(76 mm)

Advertisement

Table of Contents
loading

Table of Contents