B. Wiring Requirements
IntelliFire Touch
Ignition System Wiring
®
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 6.3, IntelliFire Touch Wiring Diagram.
• This appliance is equipped with an IntelliFire Touch
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
IFT-RC400
REMOTE
CONTROL
(OPTIONAL)
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
Figure 6.3 Intellifire Pilot Ignition (IPI) Wiring Diagram
Outdoor Lifestyles by Hearth & Home Technologies • TWILIGHT-IFT Installation Manual • 2668-970 Rev. C • 3/21
FLAME
SENSE IGNITER
6 VAC
TRANSFORMER
IFT CONTROL
IFT AUX MODULE
MODULE
Wi-Fi Module
(OPTIONAL)
RF Module
BLK
RED
APPLIANCE
ON/OFF
CONTROL BRN BLK
(OPTIONAL)
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
JUNCTION BOX
110-120 VAC
TO JUNCTION
BOX 110-120 VAC
(OPTIONAL)
3 PRONG 110VAC
(OPTIONAL)
NOTE: For fan wiring options
see instructions provided with
available fan kit.
6V DC
BATTERY PACK
2326-013