Electrical Information; Wiring Requirements; Intellifire Pilot Ignition System Wiring; Wiring The Junction Box - Hearth & Home Outdoor Lifestyles ODCOUG-36NR Installation Manual

Hide thumbs Also See for Outdoor Lifestyles ODCOUG-36NR:
Table of Contents

Advertisement

5 5

Electrical Information

A. Wiring Requirements
Note:
The Courtyard appliance MUST be connected to
a GFCI (Ground Fault Circuit Interrupt) protected circuit
breaker.
WARNING! Risk of Shock or Explosion! DO NOT wire
110-120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
Total Electrial Requirements: 110-120Vac, 60Hz., less
than 3 Amperes
• Wire the appliance junction box to unswitched 110-
120 VAC. This is required for proper operation of the
appliance.
• A 110-120 VAC circuit for this appliance must be
protected with ground-fault circuit-interrupter protection
in compliance with the applicable electrical codes.
• Low voltage and 110-120 VAC voltage cannot be shared
within the same wall box.
B. IntelliFire Pilot Ignition System Wiring
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
THIS APPLIANCE SUPPLIED STANDARD WITH:
• IntelliFire control valve (6V)
• Wall Switch Control - Operates unit On/Off
• Wall switch wire
C. Wiring the Junction Box
Junction box wiring on this appliance can be done from
either inside or outside of the appliance. However, for
ease of installation, it is recommended that the junction
box be wired from outside of the appliance.
If the junction box is wired from OUTSIDE appliance:
• Remove the screw attaching the junction box cover to the
outer shell. Pull junction box cover out to disengage it
from the outer shell. See Figure 5.1.
Outdoor Lifestyles by Hearth & Home Technologies • Courtyard Installation Manual • 4150-901 Rev. A • 04/23
Figure 5.1 Junction Box Cover Removal
Install electrical wires from outside the appliance
through the hole in the cover plate and secure wires
with a Romex connector.
Make all necessary wire connections to the junction
box and reattach the cover plate to firebox outer shell.
See Figure 5.2.
Figure 5.2 Reattaching Junction Box Cover
D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors could
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.