5 5

Electrical Information

A. Wiring Requirements
Note:
The Courtyard appliance MUST EH FRQQHFWHG WR
D *)&, *URXQG )DXOW &LUFXLW ,QWHUUXSW SURWHFWHG FLUFXLW
EUHDNHU
WARNING! Risk of Shock or Explosion! DO NOT wire
110-120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
Total Electrial Requirements: 110-120Vac, 60Hz., less
than 3 Amperes
‡ :LUH WKH DSSOLDQFH MXQFWLRQ ER[ WR XQVZLWFKHG 
120 VAC. This is required for proper operation of the
appliance.
‡ $  9$& FLUFXLW IRU WKLV DSSOLDQFH PXVW EH
protected with ground-fault circuit-interrupter protection
LQ FRPSOLDQFH ZLWK WKH DSSOLFDEOH HOHFWULFDO FRGHV
‡ /RZ YROWDJH DQG  9$& YROWDJH FDQQRW EH VKDUHG
ZLWKLQ WKH VDPH ZDOO ER[
B. IntelliFire Pilot Ignition System Wiring
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
THIS APPLIANCE SUPPLIED STANDARD WITH:
‡ ,QWHOOL)LUH FRQWURO YDOYH 9
• Wall Switch Control - Operates unit On/Off
• Wall switch wire
C. Wiring the Junction Box
-XQFWLRQ ER[ ZLULQJ RQ WKLV DSSOLDQFH FDQ EH GRQH IURP
either inside or outside of the appliance. However, for
ease of installation, it is recommended that the junction
ER[ EH ZLUHG IURP RXWVLGH RI WKH DSSOLDQFH
,I WKH MXQFWLRQ ER[ LV ZLUHG IURP 2876,'( DSSOLDQFH
• 5HPRYH WKH VFUHZ DWWDFKLQJ WKH MXQFWLRQ ER[ FRYHU WR WKH
RXWHU VKHOO 3XOO MXQFWLRQ ER[ FRYHU RXW WR GLVHQJDJH LW
from the outer shell. See Figure 5.1.
Outdoor Lifestyles by Hearth & Home Technologies • Courtyard Installation Manual • 4150-901 Rev. B • 06/23
Figure 5.1 Junction Box Cover Removal
Install electrical wires from outside the appliance
through the hole in the cover plate and secure wires
with a Romex connector.
0DNH DOO QHFHVVDU\ ZLUH FRQQHFWLRQV WR WKH MXQFWLRQ
ER[ DQG UHDWWDFK WKH FRYHU SODWH WR ¿UHER[ RXWHU VKHOO
See Figure 5.2.
Figure 5.2 Reattaching Junction Box Cover
D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors could
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
15