Good Faith Wall Surface/Tv Guidelines - Hearth & Home Outdoor Lifestyles TWILIGHT-IFT NG Installation Manual

Table of Contents

Advertisement

B. Good Faith Wall Surface/TV Guidelines
Figure 2.1 references the maximum interior wall surface
temperatures above the appliance.
FIREPLACE
OPENING
Figure 2.1 Maximum Interior Wall Surface Temperatures Above
Appliance
NOTICE: Surface temperatures listed above are taken with
a temperature measuring probe as prescribed by the test
standard used for appliance certification. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 °F (17 °C) or
more depending on the thermometer settings and material
characteristics being measured. Use appropriate finishing
materials that are able to withstand these conditions. For
additional finishing guidelines, see Section 8.
8
Outdoor Lifestyles by Hearth & Home Technologies • TWILIGHT-IFT Installation Manual • 2668-970 Rev C • 3/21
TO CEILING
120°F
130°F
140°F
48 in.
42 in.
150°F
36 in.
160°F
30 in.
180°F
24 in.
18 in.
200°F
12 in.
6 in.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
APPLIANCE FRONT

Advertisement