Type 8692/8693
CANopen
3.46 0x2C23
sub name
0x02 mERRpinp_func
0x04 mSPOSpinp_func
3.47 0x2C39
Only for FMR-devices
sub name
0x01 FMRtemp
0x02 FMRdens
0x03 FMRdiam
0x04 FMRkvselect
0x05 FMRsens
0x06 mPCONleak
3.48 0x2C42
sub name
SP_UserUnit
Bedienungsanleitung Software
SensorBreak
description
0: signal break detection of PV inactive
1: signal break detection of PV active
0: no safepos when PV signal break detected
1: safepos when PV signal break detected
F.Control
description
Temperature of medium
Density of medium
Diameter of valve
Selection of kv charact
0: factory charact
1: user charact
Source of medium temperature
0: Manual (2C29sub1)
1: analog input
2: BueS/fieldbus (2542sub1)
0: Leakage inactive
1: Leakage active
SP_UserUnit
description
SP in user unit which is shown on display
X
RW
X
RW
X
RW
X
RW
X
RW
X
RW
X
RW
X
RW
RWW