Components

3.18.2 Repair procedures

To remove the swing raster motor
Service manual
182
Pins
1-2
1-3
1-4
1-5
2-3
2-4
2-5
3-4
3-5
4-5
Swing raster motor resistance
measurements are correct?
Yes
No
Class 20~42 indoor unit
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the switch box, see
2 Put a small drain pan (or container) under the drain hose.
3 Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.
Measured resistance (Ω)
353.4~406.6
706.8~813.2
Action
Replace the swing raster motor wiring
harness, see
"Repair
4
procedures" [
Replace the swing raster motor, see
"Repair
procedures" [
"3.14 Plate
4
"3.14 Plate
work" [
 151].